Re: question about bathroom in a basement
Posted by Deb on January 05, 2004 at 20:40:24:
In response to Re: question about bathroom in a basement
: We have a 4 year old home with an ejection pump
: built into the concrete floor. The problem:
: we want to place the toilet and sink about 20' away
: from the rough-in. Is it possible to extend the
: pipes from the exsisting pump to the more desirable
: location?

: thanks

This is a big project. The concrete will need to be taken up, new drainage lines run and new vents run. Many times underslab plumbing and ejectors are installed with minimal depth and grade. You may not be able to move the lines and maintain grade without also lowering the ejector. A 20' move means you need 5 more inches of drop.
Deb