Re: WELL PUMP PRESSURE SWITCH
Posted by Deb on December 07, 2003 at 21:20:01:
In response to Re: WELL PUMP PRESSURE SWITCH
: My pressure switch keeps kicking on and off on the high end of the pressure sitting. I have replaced the pressure switch and it still does it.

Check the air in the pressure tank with the water drained. It should be 2#s less than the kick on pressure for the pump. Also, check the nipple that connects the pressure switch to the rest of the works to make sure it is clear of any obstruction.
Deb
The Pipewench


Replies to this post
There are none.