Re: Drain vent
Posted by Terry Love on June 12, 1998 at 01:40:33:
In response to Re: Drain vent
: What size pipe should I use for the new vent pipe?

1-1/2" for the vent which can be revented in the attic to the main vent stack.

What size pipe for the pipe connecting the tub drain (5 feet away) to the house drain.? Thanks.....chris

1-1/2" for the trap and trap arm(up to 42") then the 1-1/2" vent, from this point, run 2" to the existing plumbing.