Re: Concrete floor - "drop in flange"


[ Follow Ups ] [ Post Followup ] [ Back to Terry Love's WWWBoard ] [ FAQ ]

Posted by Bud..Suncoast Plumbing Inc. on May 28, 1999 at 06:53:32:

In Reply to: Concrete floor - "drop in flange" posted by elliott on May 27, 1999 at 21:39:04:

Elliott: There is a closet flange that can be used in situations such as yours. It does in fact slip down inside the existing closet bend, and an effective seal is created by tightening down four screws that compress a neoprene gasket against the original pipe. There is a provision on this new closet flange to secure it to the floor for added stability(use stainless steel lag bolts for this). Lots of luck...Bud


Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:

Optional Link URL:
Link Title:
Optional Image URL:


[ Follow Ups ] [ Post Followup ] [ Back to Terry Love's WWWBoard ] [ FAQ ]